Simulation setup ================ ``flow`` -------- Non-empty OPM Flow command and flags. pofff adds the output directory. Include ``--enable-tuning=true`` when injection rows contain TUNING values. ``grid`` -------- Accepted values are ``cartesian``, ``tensor``, and ``corner-point``. Cartesian grids require one entry in ``x`` and ``z``. Corner-point grids require 11 entries in ``z``. ``thickness`` and ``mult_thickness`` ------------------------------------ Select ``initial`` or ``final`` measured thickness, or provide a positive physical thickness. ``mult_thickness`` is a positive multiplier. ``x`` and ``z`` --------------- Positive integer refinement arrays. Their interpretation depends on ``grid``. ``temperature``, ``pressure``, and ``diffusion`` ------------------------------------------------ ``temperature`` contains bottom and top values [°C]. ``pressure`` is positive [Pa]. ``diffusion`` contains liquid and gas coefficients [m²/s]. ``sources`` and ``inj`` ----------------------- ``sources`` has two ``[x, z]`` rows [m]. Each injection row contains injection time [s], write time step [s], rates for sources 1 and 2 [kg/s], and optionally one TUNING string.