Grid and geometry#
length, width, and thickness#
Type: positive number. Units: metres. Required: yes. These values set the physical length, height, and extrusion depth of the microsystem.
length = 6.74e-3
width = 2.5e-3
thickness = 0.03e-3
lineWidth#
Type: positive number. Controls contour line width in generated diagnostic figures. It does not affect the mesh.
channelWidth#
Type: positive number. Units: metres. Controls the top and bottom channel
width in device mode.
meshSize#
Type: positive number. Units: metres. Sets the target Gmsh element size.
Generated meshes with element sizes 1e-4 m and 1e-5 m.#
Geometry modes#
image.mako sets the computational domain to the image extent.
device.mako creates the micromodel geometry described by Benali (2019) and
Liu et al. (2023). Grain surfaces and device walls use no-slip conditions. The
templates can be modified for other element types or device geometries.
Geometry of the device mode.#